In the 744 sim both outflow valves open and with all packs running results in a 4000fpm cabin ROC. One outflow valve is about the size of four windows... I would infer from this that the packs can probably keep pressurisation at level with two or three busted windows, hence no explosive decompression would ensue from that. Peel off some skin or blow out a cargo door of course and that's a different story...