In "Fail Operational" each autopilot uses a different electrical source so that guidance isn't lost at a critical time. All 3 autopilots are engaged in CAT3B operations, so if you have a single electrical failure close-in, you can still complete the approach, ie the remaining autopilots will flare, touchdown and track centerline.