PPRuNe Forums - View Single Post - Airbus dual engine failure - Why no yellow elec. pump on ?
Old 6th Sep 2019, 05:39
  #4 (permalink)  
iggy
 
Join Date: May 2004
Location: Ziltoidia... indeed'd.
Posts: 484
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by vilas
I had asked this to Airbus. They do not have any objection. They replied that when windmilling RPM becomes low to cause Yellow system low pressure ECAM will ask to switch on yellow pump. Only thing is that the yellow Elec pump has fluid turn over of 65L/mt. as against 145L/mt of EDP so it is not capable of supporting the PTU.
Hi Vilas,

Any reason then for Airbus not to write this option as possible in the manuals?

Thanks!
iggy is offline