PPRuNe Forums - View Single Post - TCAS/REAC W/S DET inoperative in case of RA 1+2 FAULT on A320
Old 26th May 2019, 09:39
  #9 (permalink)  
sonicbum
 
Join Date: Mar 2012
Location: Having a margarita on the beach
Posts: 2,423
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by Fursty Ferret
It almost certainly is inop, but if the ECAM had to show the true list of inoperative systems following dual RA failure you'd still be reading them a week later.
It is not mentioned as an INOP system neither on the ECAM nor in the FCOM, hence it is very unlikely that it will be inop. As far as I remember the PWS takes position information from the EGPWS/T2CAS
sonicbum is offline