PPRuNe Forums - View Single Post - Inop outflow valves and gradual decompression
Old 17th September 2018 | 12:56
  #3 (permalink)  
BAengineer
 
Joined: May 2018
Posts: 8
Likes: 0
From: London/Fort Worth
No - in cruise the valves are almost full closed (flight segment with max diff px) so if they fail in that position and the cabin pressure starts to fall then you cannot increase the pressure by closing that valves further as they are inop. Depressurization will continue until the diff px gets to a point that corresponds with the fixed valve position.
BAengineer is offline  