John
As always, I was using:
a = Sqrt(gamma x R x T)
At a guess, gamma would be between 1.3 and 1.35 for a core nozzle outlet mixture, and I would be the first to admit that the temperature is pure guesswork. I am glad you were able to corroborate the principle, though.
Thanks.
Pie