PPRuNe Forums - View Single Post - A320 Emer Elec short before v1
View Single Post
Old 19th Mar 2018, 13:37
  #19 (permalink)  
Goldenrivett
 
Join Date: Jan 2014
Location: N5109.2W10.5
Posts: 720
Likes: 0
Received 0 Likes on 0 Posts
vilas
If the rat doesn't deploy you go in mechanical backup.
Why?

According to QRH, you don't loose all 5 fly-by-wire computers or both elevators or total loss of ailerons and spoilers if the RAT doesn't deploy. You'll have "BAT Only" power available (until it runs flat).