On earlier Airbus types a boost pump in each inboard tank pressurised a small valve allowing the refueling manifold to drain into the inboard tank after refueling with the aircraft pumps then switched on. During refueling when the selected quantity was reached the refuel valve for that tank would close but if the boost pump was running fuel would still enter the inboard tank uncontrolled through the drain valve.