PPRuNe Forums - View Single Post - Yorkshire Air Ambulance Exodus
View Single Post
Old 10th Jan 2018, 18:48
  #29 (permalink)  
Flying Bull
 
Join Date: Feb 2006
Location: Germany
Posts: 919
Received 5 Likes on 3 Posts
Originally Posted by ThomasTheTankEngine
But does that include a 2 minute or 30 second OGE OEI hover or a fly away option?
Hi, as long as you operate underneath the Blue line:
Blue line: OEI power limit: Shows the maximum power that will be available at the OEI 30 second limit in case of a sudden engine failure.

But chances are high, if you wonˋt lift off with MTOW at the begining, that you will be able to continue with one engine within the 2 Minute rating which then extends to 2:30 (if 30 sec rating wasnˋt used) or even with some wind wonˋt even need to touch emergency Power at all.

With 700kg Fuel you have an endurance of roughly 3hrs, so itīs quite easy to add some extra reserves not topping up fully!
Flying Bull is offline