For CFM56 engines on the A320 during engine start , we receive an ECAM “start valve not closed”. After this procedure is complete , are we required to do a dry crank before doing the manual start valve procedure ? Thanks |
No, the engine had essentially started, there is no residual unburnt fuel in the cans.
|