PPRuNe Forums

PPRuNe Forums (https://www.pprune.org/)
-   Tech Log (https://www.pprune.org/tech-log-15/)
-   -   A320 SOP (https://www.pprune.org/tech-log/572373-a320-sop.html)

Flyman35 27th December 2015 06:47

A320 SOP
 
http://healthylivingstuff.com/wp-con...9.36.07-AM.png

Hi fellow pilots, in SOP ,during securing the aircraft it states Batteries off,wait 2 minutes (does that apply in case of connected external power or no?

FlightDetent 27th December 2015 17:56

If the EXT PWR remains connected, there is probably no technical reason to wait.

I found that if EXT PWR is available the time lapsed between me shutting the APU OFF and performing the securing actions is well above 2 minutes anyhow. This particular piece of SOP is written for the case when you leave the aircraft withou GPU connected, I think.

FD.

vilas 28th December 2015 05:36


Originally Posted by FlightDetent (Post 9221650)
If the EXT PWR remains connected, there is probably no technical reason to wait.

I found that if EXT PWR is available the time lapsed between me shutting the APU OFF and performing the securing actions is well above 2 minutes anyhow. This particular piece of SOP is written for the case when you leave the aircraft withou GPU connected, I think.

FD.

The two minutes wait is for the APU flap to close if done earlier thare will be smoke in cabin during next start. Whenever it is closed batteries can be switched off.


All times are GMT. The time now is 09:22.