PPRuNe Forums

PPRuNe Forums (https://www.pprune.org/)
-   Tech Log (https://www.pprune.org/tech-log-15/)
-   -   777 CAT3B app with one gen failed (https://www.pprune.org/tech-log/365291-777-cat3b-app-one-gen-failed.html)

Bungfai 9th March 2009 11:43

777 CAT3B app with one gen failed
 
777 making CAT3B approach, with LAND3 annunciated and one engine gen failed. Do we have to go around? Or can still go on with CAT3B approach.Thanks.

camber 9th March 2009 14:34

From an Autoland perspective, continue and land. The ASA will indicate LAND 3, so no downgrade required. In fact, with only one backup Gen operating the B777 is still CatIIIA capable, as the ASA will indicated LAND 2.

Swedish Steve 9th March 2009 15:13


The ASA will indicate LAND 3
But be careful. Not all CAT 3 required items are monitored by the system.
Not to worry about on finals, but items like Windscreen wipers! must be S for Cat 3 approach, but not monitored.

Henry VIII 9th March 2009 15:40

On the bus QRH there is a list of non monitored sys/devices with correspondent limitation(s).
Isn't there on 777 ?

MrFixer!!! 9th March 2009 15:55

Going back to the original thread, only 1 Generator out shouldnt be a problem at all, according to Boeing 777s have 6 generators (in Total):ok: and only 1 failing should not result in any downgrade from CAT3 !!!

Bungfai 10th March 2009 00:38

Thank you. No, boeing doesn't state anything concerning non monitering items on QRH. Will be nice to have.

TAC inop. 10th March 2009 01:22

Depends when the failure occured.

Check the inhibited items, different levels for the stages of approach
eg. <1000' , ABP & SOPS
<200'


All times are GMT. The time now is 12:18.