45737 17th March 2008 10:49

Man Rat On
 
Hi all FBWirer, anyone knows is there any different MAN RAT ON on the Hydraulic Panel and Emerg Elec Panel on 320, or this is an identical switch?

fantom 17th March 2008 11:26

Next time you are in the sim, ask to have a look.

Bring up the HYD page and press the HYD RAT button. The RAT will deploy but the electrics page is unaffected. Restore.

Now pull up the electrics page and press MAN RAT. The RAT will deploy and the EMER GEN will run. GENs 1 and 2 will still power AC1 and AC2 but you will see that the centre of the page has changed subtly. All you have done is screw up the electrics but everything still works.

f

avionneta 17th March 2008 12:47

to summarize
with HYD RAT MAN ON you've got the pressurisation of the blue hydarulic circuit only
with RAT & EMER GEN MAN ON, you've got both the preceding & the emergency generator (emer gen driven by an hydraulic motor)

45737 17th March 2008 14:09

Well,thk for sharing, I will try soon ( in SIM:O),since FCOM1 not mentioned clearly...

avionneta 17th March 2008 21:26

I would say you've read it a bit too fast maybe