PPRuNe Forums

PPRuNe Forums (https://www.pprune.org/)
-   Tech Log (https://www.pprune.org/tech-log-15/)
-   -   why is there no CAT III plates? (https://www.pprune.org/tech-log/258568-why-there-no-cat-iii-plates.html)

genius747 4th January 2007 19:54

why is there no CAT III plates?
 
Hey,

I was thumbing through my jeppy - TUK04, Heathrow, Manchester, Liverpool etc etc.. and no CAT III approach plates, just CAT I & II. ~Very confused?

Help please!

Thanks gang

G74

TolTol 4th January 2007 22:21

Same as CATII plates except RA = 50ft, and min RVR = 200m. Just make sure the runway is CATIII approved first.

genius747 5th January 2007 02:43

I still don't understand why, major international airports such as EGLL would not publish, and jeppesen print a CAT III plate!!.... confusion must come from this. Shooting a CAT III B Approach off a CAT II Plate! I don't know..........

Tree 5th January 2007 04:59

Pages 11-1A, 11-2A, 11-3A, 11-4A are all CATII/III.
You may print them yourself from the Jepp Website.

chevvron 5th January 2007 06:22

Genius 747: EGLL do not publish their own plates; they're published by the UK CAA then copied by private companies Jeppesen, who are un-regulated, thus they can print what they like.
Correction; for un-regulated read self-regulated.

sarah737 5th January 2007 07:34


Originally Posted by genius747 (Post 3051063)
Hey,
I was thumbing through my jeppy - TUK04, Heathrow, Manchester, Liverpool etc etc.. and no CAT III approach plates, just CAT I & II. ~Very confused?
Help please!
Thanks gang
G74

Why would you need CAT III plates??
Unlike in CAT I and II the DH and RVR in CATIII are only aircraft related and the same in the whole world. At DH you will always be over the runway. The only thing you have to know is if the runway is CATIII or not.

alatnariver 5th January 2007 08:11

... and if you like Jeppesen would design and print a taylord copy of a CAT II and CAT III approach for your airline, or your self if you like to spend the money involved in taylored charts :} .

Most companies I used to work for, used only the standard set issued by Jeppesen and we had to use a list where for each airport and each runway the applicable minima and req'd. RVR values was published. Was easy to use and not a big issue :rolleyes: . For "the rest" of the approach the CAT II chart is sufficient, as except for the minima box there would be not much of a change.

CoolHandleLuke 5th January 2007 08:16

My company uses Jeppesen charts.

We have tailored Jeppesen charts for CAT II/III plates with our company name printed on the header. Slightly easier to use than what alatnariver describes but probably a lot more expensive!!

RYR-738-JOCKEY 5th January 2007 09:32

Why on earth shall we have to search for a small text on the airport diagram plate stating CATII/III...? It's simply rediculous. Sometimes (when diverting for instance), you don't have any time to waste.
But more importantly is that for CATIIIa, minima is not 50 feet RA...it's less than 100 down to 50 feet RA. So lets say the CATII minima is 105 RA for a specific approach, how can we just set 50 RA for a CATIIIa approach using the same plate?? To spell it out, how can it be that if the JAR-OPS CATII system minima can not be applied for an approach, why shall we automatically apply the system minima for a CATIIIa approach?
For that very reason it would have been sooooooo much easier with the damn plate in our hands.

Permafrost_ATPL 5th January 2007 11:52


why shall we automatically apply the system minima for a CATIIIa approach?
Because we don't.

Have a look at the front of the TEXT Jepp binder and you'll find the Cat II/III minima for each airport and runway. Everything else on the plate is the same. I'm a bit concerned you didn't know that (if your alias is what you do).

P

RYR-738-JOCKEY 5th January 2007 12:12

"Have a look at the front of the TEXT Jepp binder and you'll find ..."

Well, we don't carry a complete Jepp binder. We assemble a tripkit containing plates for dest+alternates. But anyway, thanx for the info. I have done alot of CATIIIa's and to my understanding the 50 RA is what we use. It has indeed puzzled me for a long time but I now understand that it is because of specific RYR ops...not having the complete binder onboard.

Permafrost_ATPL 5th January 2007 13:00

I'm glad there is a logical explanation ;-)

P

Seat1APlease 5th January 2007 13:18


Originally Posted by RYR-738-JOCKEY (Post 3052119)
"
Well, we don't carry a complete Jepp binder. We assemble a tripkit containing plates for dest+alternates..

Sounds rather a dubious practice. What happens if you're halfway there and need to put down somewhere in a hurry with a fire or whatever? If you only have plates for destination, alternates, and a few company stations on the way then you could find yourself very limited indeed.

J.O. 5th January 2007 13:28

The simple answer to the originally posted question is that Jeppesen's standard subscription service does not include CATIII charts. They must be ordered on an individual basis. The reason for this is that CATIII certification is based upon state approval, and in some cases, different operators have different CAT III RVR minima, depending on the aircraft equipment, training and experience, and the regulations of the state of registry.

CoolHandleLuke 5th January 2007 14:04


Originally Posted by J.O. (Post 3052229)
The reason for this is that CATIII certification is based upon state approval, and in some cases, different operators have different CAT III RVR minima, depending on the aircraft equipment, training and experience, and the regulations of the state of registry.


Is there then a difference between airport facilities for CATII and CATIII?
I mean is the only difference between II and III aircraft equipment and training etc.?

Or is there also different criteria concerning ILS sensitive areas, ground equipment and so on?

issi noho 5th January 2007 14:29

738 jock

The cat 2 minima may be 105 ra, but that would still be 100 ft above the runway, most likely a dip in terrain on approach, sometimes the cat 2 is 80 ra but you wouldn't be permitted less than system minima. There is no cat2 (for cat c or above) to MAN 6r due to the valley on approach but you can still do cat3.

IN

RYR-738-JOCKEY 5th January 2007 16:07

Permafrost wrote: "I'm glad there is a logical explanation ;-)"
Yep...it's not my fault ;-)
No, but seriously the reason for my attitude is that I believe that we're not applying the correct minima in some cases. We always (at least to my understanding) use the 50 RA for CATIIIa which I believe is wrong.
As in my example of a CATII minima of 105 RA, I presume the CATIIIa would be higher than 50, perhaps 55...
I believe J.O. has the answer for my case.
(Seat1APlease: Of course we carry plates for unforeseen diversions enroute..."emergency bricks" which we in normal ops don't open. BTW did you know that seat 1a has the highest death potentional in a crash? :E )

hoey5o 5th January 2007 16:38

Issi Noho,

You cannot do any form of low vis approach on to 06R at Man !

The ILS is a Cat1 installation only.

If Cat11 is not available you can bet your bottom dollar Cat111 is out as well.


If all else fails Aerad enroute supplements will tell you what the airfield is capable. (or ATC of course)

JW411 5th January 2007 18:52

issi noho:

"..sometimes the Cat 2 is 80 ra but you wouldn't be permitted less than system minima."

Can you explain this to me please?

issi noho 5th January 2007 20:17

1. My mistake I should have said MAN 06L

2. when the approach is surveyed/tested 100 ft above the runway threshold on the glide path is calculated and ground beneath that point in space (most likely approach lights not runway) is also surveyed if this happens to be a small mound it is quite feasible that the RA displayed when the ac is 100 ft above threshold elev may be 80 ft. Your ops manual, if your submission for cat2 approval was thorough enough, should have guidance on this to avoid pilots thinking the minima they use is rubbish.

3. By virtue of the fact most airports don't surround themselves with small hills it is more likely to have a dip in the ground surrounding a runway hence you often see CAT 2 minima of 105 or 110. This is still 100ft above runway threshold.

4 CAT 3 is very definitely above the runway at decide 50ft is therefore correct.

5. MAN 06L has minima for Cat2 for catB ac but not C/D due to erroneous RA readings at decide associated with the higher speeds and the river cutting below. CAT3 is permitted all cats

Hope this clarifies my point.
IN


All times are GMT. The time now is 12:52.