Aibus A340 ECAM question
What is an ENG MINOR FAULT ?
What is the reason for the operating procedure for an ENG 3 MINOR FAULT ? Thanks for any answers |
An ENGINE MINOR FAULT is a level 1 alert advisory.
I had previously thought that it was a 'go without condition' message/repair within XXX hrs, but have just read that if it's an ENG 3 MINOR FAULT, 'yellow elec hyd pump' p/b switch must be selected to off position after pushback to prevent activation of the pump after takeoff. It is returned to auto position after landing/shutdown for cargo door ops. Hope this helps cod |