PPRuNe Forums

PPRuNe Forums (https://www.pprune.org/)
-   Tech Log (https://www.pprune.org/tech-log-15/)
-   -   A-320 Datalink ATC and Company fault (https://www.pprune.org/tech-log/602139-320-datalink-atc-company-fault.html)

Jimmy Hoffa Rocks 20th Nov 2017 09:10

A-320 Datalink ATC and Company fault
 
What causes these ATSU multiple faults, ECAM Datalink and Company faults.
also combined with the ADS-B?

Related to the ground stations ?

Also is it related to a software problem ?

There is a modification right that fixes this right?

annoying ECAM pings.

Thanks in advance

gnarlberg 20th Nov 2017 13:25

i hate this ! besides APU inop MEL the worst on the bus !

Bluejet 21st Nov 2017 09:10

There is a lot going on with this. Generally the majority of faults are with the system picking up two similar strength signals at the same time. It will always default to the stronger signal but if that fluctuates then it will cause a fault. A good example is at EGGW, the a/c frequently gets a fault caused by atmospherics when STN briefly becomes the stronger signal. As this fluctuates the a/c swaps back and forth a few times then gives up. EGGW has tried to fix it by moving the antenna to a better location which has helped a lot. It also happens for similar reasons in flight with ground station signals (especially in a high provision area where there are more signals to choose from). Don't be tempted to enter the MCDU and change the provider though as it is immensely expensive if your airline does not have a contract with the new provider, and whilst it may start giving you weather you will lose any company comms facilities.

Down Three Greens 21st Nov 2017 22:45

Check the mod state of VHF 3.

https://ext.eurocontrol.int/WikiLink/index.php/VDR_deafness

https://ext.eurocontrol.int/WikiLink/index.php/Service_Bulletins_for_VDR_Deafness_Update


All times are GMT. The time now is 10:50.


Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.