PPRuNe Forums

PPRuNe Forums (https://www.pprune.org/)
-   Tech Log (https://www.pprune.org/tech-log-15/)
-   -   A320 Pump Pressures Wing & Center Tnk (https://www.pprune.org/tech-log/593435-a320-pump-pressures-wing-center-tnk.html)

arrow28 13th Apr 2017 01:52

A320 Pump Pressures Wing & Center Tnk
 
Hi
As there is a preferential use of Center Tank over Wing Tank fuel, does anybody know what the pumps pressure at the wing and center are?

Thanks

applecrumble 13th Apr 2017 07:08

There are sequence valves. The pumps are identical but the sequence valves fitted to the pumps from the wing ensure the center tank fuel is used first.

Goldenrivett 13th Apr 2017 17:07


does anybody know what the pumps pressure at the wing and center are?
From Eaton's web site: Airframe Fuel Pumps
Type 8410 (A320 wing tank) Delivery Pressure . . . . . . . . . . . . . . 200kPa (29psig)

IFixPlanes 19th Apr 2017 17:39

All Pumps deliver the same pressure.
The sequence valve is simply spoken a check valve with different spring tension.
The sequence valves in the wing reduces the output pressure to 25 PSI, thus giving priority to the center tank pumps, whenever they are operating.

FlightDetent 19th Apr 2017 19:45

Excellent, thank you. Now all I have to do is find somebody :O to tell me where in the system schematic are the sequence valves located. I am thinking you see, about how do 4 PSI reducing springs downstream of wing pumps fit into the gravity feeding arrangement. (that is a question)

Then the first prize from the next pilot's ATA28 wisdom measuring contest is surely mine! :E

tubby linton 19th Apr 2017 20:34

Sequence valves are pressure relief valves attached to the secondary outlets on the wing tank pumps only. These valves prevent the pump outlet pressure rising above 25 psi. This pressure is lower than center tank pump output pressure and therefore permits center tank delivery to predominate.
The main engine fuel pump is powered by the accessory gearbox driven by the engine, and this is what delivers fuel to the engine even if the tank pumps have failed.

FlightDetent 19th Apr 2017 20:42

Secondary outlet ... where? http://www.eaton.com/ecm/idcplg?IdcS...Name=CT_194798

Jet II 19th Apr 2017 21:07

Have some pictures..

http://i97.photobucket.com/albums/l212/sids666/pump.jpg


http://i97.photobucket.com/albums/l2...s666/pump2.jpg


http://i97.photobucket.com/albums/l2...s666/pump3.jpg

FlightDetent 19th Apr 2017 21:19

Thank you.

readback: The pumps provide identical pressure but actually the pressure coming from the wing tank pump's canister is less, effect of a "sequence valve" PRV designed to open at 25 psi.


All times are GMT. The time now is 08:02.


Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.