100.above 16th Feb 2013 11:01

A320 - APU BLEED PRESS INDICATION
 
Hello There,

So the books say amber XX's will be shown if ADIRS2 is N/A or OFF or if signal from ECB is invalid/not sent.
  • does anyone know what it is actually referencing from the ADIRS?
  • Is it using a static pressure or something as a reference?

You would think a pressure sensor would be something simple and independant.

Another funny thing is if I compare 2 different FCOM's I have found, one being recent 2012. The 2012 one says it uses ADIRS1 and the old ones on smart cockpit state ADIRS2.

Fairly useless thing to know but I cant help to ask out of interest! :}

gAMbl3 16th Feb 2013 16:06

For 320(classic) its ADIRS2 whereas for 319 and 321(enhanced) its ADIRS1

rudderrudderrat 16th Feb 2013 23:15

Hi 100.above,

You would think a pressure sensor would be something simple and independent.
It is. It simply measures the total pressure.
In order to display the Delta pressure, the system needs to know the ambient Pressure also.

100.above 17th Feb 2013 00:39

Hi rudderrudderrat & gamblr3,

Thanks for your responses! :ok:

Makes sense now :D

Did you guys look at an engineering manual or something to find this out?

AVApilot 17th Feb 2013 14:08

Delta pressure
 
Hello Rudderrudderrat,

You say that "In order to display the Delta pressure, the system needs to know the ambient Pressure also." But the APU system page does not show any kind of delta pressure, I'm confused, maybe you can elaborate a liitle more?

Thanks in advance.

rudderrudderrat 17th Feb 2013 16:09

Hi AVApilot,

It looks like this:

http://www.blackholes.org.uk/PP/APU%20ECAM.jpg
Note 3
or like this
http://www.blackholes.org.uk/PP/APU%...20Pressure.jpg

Silky 17th Feb 2013 16:21

To register any pressure indication it firstly requires a reference pressure which is what you get once ADIRU 1/2 is turned on as they then power the static system!
HOPE THAT HELPS :)

rcmoraes 19th Feb 2013 18:14

i've noted that with all ADRs off you wont have the bleed indication on the apu page, but you whill have it on the bleed page (apu supling). any ideas why ?