A320 fuel/tank feed at engine start
Thread Starter
Join Date: Jul 2015
Location: USA
Posts: 21
Likes: 0
Received 0 Likes
on
0 Posts
A320 fuel/tank feed at engine start
I have heard many differing opinions so I am looking to Europe to answer the question. At engine start, where is fuel
supplied from? The Centre tank or the wing tank? After both engines are started I believe the centre tanks feed the engines until slat extension. My question is specifically upon the first engine start.
thanks
supplied from? The Centre tank or the wing tank? After both engines are started I believe the centre tanks feed the engines until slat extension. My question is specifically upon the first engine start.
thanks
This has me intrigued.
I have been flying the bus for a very long time and always thought the wing tanks fed the engines during start. I am certain that FCOM said something similar to “the CTR tank pumps run for two minutes AFTER engine start”.
BUT
I have just started reading through my newly issued company manuals on the IPAD and they have all been ….”customized” since I last flew in 2020 and are no longer simply copies of FCOM.
And reading the fuel system it clearly states:
“If fuel is in the CTR tank, the pumps run AT engine start for 2 minutes”
followed by
“They will also run before OR after the engine start sequence if the slats are retracted”.
So this implies the CTR tank is providing fuel during start?
Its no big deal, knowing this doesn’t impact the operation but it certainly goes to show that not all is what you think it is!
I have been flying the bus for a very long time and always thought the wing tanks fed the engines during start. I am certain that FCOM said something similar to “the CTR tank pumps run for two minutes AFTER engine start”.
BUT
I have just started reading through my newly issued company manuals on the IPAD and they have all been ….”customized” since I last flew in 2020 and are no longer simply copies of FCOM.
And reading the fuel system it clearly states:
“If fuel is in the CTR tank, the pumps run AT engine start for 2 minutes”
followed by
“They will also run before OR after the engine start sequence if the slats are retracted”.
So this implies the CTR tank is providing fuel during start?
Its no big deal, knowing this doesn’t impact the operation but it certainly goes to show that not all is what you think it is!
A lot of people on this site are just so bitchy.
How about if you have nothing that enhances knowledge just keep quiet.
Anyone noticed the reduction in posts over the last few years, I'm not the only one who thinks this way.
How about if you have nothing that enhances knowledge just keep quiet.
Anyone noticed the reduction in posts over the last few years, I'm not the only one who thinks this way.
Join Date: Jul 2008
Location: The Ghetto
Posts: 42
Likes: 0
Received 0 Likes
on
0 Posts
For the 20 the wing tanks have sequence valves. Basically blow off valves. The ctr pumps run for the start until 2 mins or slats extend as per the fcom. The higher pressure from the ctr pumps wins the pressure fight and you get ctr fuel. The flscu will off the pumps as described and will restart them at slat retraction until one of the ctr low level sensors is dry then I think it’s 2 or 5 mins for scavenge then they shut off. If my memory serves me well. Hope that helps some.
Unless the cross-feed is open, each engine will only take fuel from its respective wing tank.
The fuel is fed from the centre tank and ACT tanks into the wing tanks, and is used in the sequence ACT 2, ACT 1, Centre tank, Wing tanks.
I can't find the specific text in the FCOM any more but my understanding was that around engine start the CTR pumps will run, (assuming fuel in the CTR tank), but when the Slats are out this will stop. The CTR tank pumps run presumably to allow any problems to reveal themselves on the ground that might render the CTR tank fuel unavailable for the flight. Fuel transfer is stopped during take-off and approach to prevent a tank contamination problem affecting all engines.
Edit, my post crossed with vilas
The fuel is fed from the centre tank and ACT tanks into the wing tanks, and is used in the sequence ACT 2, ACT 1, Centre tank, Wing tanks.
I can't find the specific text in the FCOM any more but my understanding was that around engine start the CTR pumps will run, (assuming fuel in the CTR tank), but when the Slats are out this will stop. The CTR tank pumps run presumably to allow any problems to reveal themselves on the ground that might render the CTR tank fuel unavailable for the flight. Fuel transfer is stopped during take-off and approach to prevent a tank contamination problem affecting all engines.
Edit, my post crossed with vilas
Busboy has it, except for one little nitpick: ctr pumps run 2min after engine start regardless of slat position for self test.
So all whites out —> all pumps run, but wings have pressure relief sequence, so ctr wins and supplies fuel for engine start and until 2min after. Then they turn off with slats (earliest 2min after eng start) , so t/o is on wing tanks.
So all whites out —> all pumps run, but wings have pressure relief sequence, so ctr wins and supplies fuel for engine start and until 2min after. Then they turn off with slats (earliest 2min after eng start) , so t/o is on wing tanks.
Only half a speed-brake
8314, I thought the same and even typed it: lights off and all run. Then deleted it, thinking the centre's are energized but may not actually run. With the normal refuelling sequence the outers are full and thus the centre pumps would be crossline green. Same logic could apply for jetpipes/transfer valves.
Care to check the books for the two of us?
Care to check the books for the two of us?
Logic 1 says ctr pumps stop with slats and at least 2min since engine start
Logic 2 says ctr pumps stop with full inner tanks until 500kg are used to prevent spillage from the IDG return. ( xfer valves (jet pump a/c) clsd until 250kg gone)
Fuel return valve only opens above a certain oil temp threshold (73°C?) but seems to have no connection with pump logic, so on ground with fuel in ctr tank wings should always be full, so ctr pumps always crossline green? Do they run at engine start for self test?
Getting more confuddled the longer I look at it. 🤔
Logic 2 says ctr pumps stop with full inner tanks until 500kg are used to prevent spillage from the IDG return. ( xfer valves (jet pump a/c) clsd until 250kg gone)
Fuel return valve only opens above a certain oil temp threshold (73°C?) but seems to have no connection with pump logic, so on ground with fuel in ctr tank wings should always be full, so ctr pumps always crossline green? Do they run at engine start for self test?
Getting more confuddled the longer I look at it. 🤔
Only half a speed-brake
My hunch is with Logic 2 you brought the answer. The general rule of self-test could still apply it seems, only achieved through a more complex logic and not just a timer.
Funny story: I once flew for an operator whose CAA thought the tank segregation for take-off was of high importance. Hence we had an SOP to time after engine start for 2 minutes, in order to observe the limitation and avoid departing with them running.