A320 APU Gen loses power with altitude
Thread Starter
Join Date: Nov 2004
Location: Here, there, and everywhere
Posts: 1,118
Likes: 0
Received 12 Likes
on
7 Posts
A320 APU Gen loses power with altitude
"A third AC generator driven directly by the APU is rated at the same power as each engine driven generator and can replace either or both engine generators at any time. However, the maximum power output of the generator decreases with altitude. "
Why?
Why?
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,396
Likes: 0
Received 0 Likes
on
0 Posts
Join Date: Sep 2007
Location: New York
Posts: 224
Likes: 0
Received 0 Likes
on
0 Posts
APU Battery Start
Perhaps you misunderstood his question. My Operator lists "Max FL for APU Battery Start" as FL250. -Both CEO & NEO. -note that's a battery start; which is what he was asking I believe. APU Max start envelope is upto the Service Ceiling, though it's no good for Bleed Air until FL225...
Normally you can start the APU anywhere in the flight envelope.
But if you’re in cruise and suddenly down both your engine generators, you’d need to descend to FL250 to start the APU.
The engine driven generators have an integrated constant speed drive to keep them running at the same speed while the engine speed varies, as the APU is either ON or OFF its generator doesn't need this feature. Dispatch with an engine generator U/S is allowable with the APU running for the entire flight. ETOPS requires a diversion in the event of an IDG failing and being unable to get the APU generator online.
The A320 is much more dependent on electrics and hydraulics then previous generations of conventional aircraft and a higher level of redundancy is called for, two generators offline and I would be looking at suitable enroute alternates rather than continuing a long flight. The emergency electrical configuration is a last resort serious emergency requiring a MAYDAY call, not to be thought of as an additional back up.
The A320 is much more dependent on electrics and hydraulics then previous generations of conventional aircraft and a higher level of redundancy is called for, two generators offline and I would be looking at suitable enroute alternates rather than continuing a long flight. The emergency electrical configuration is a last resort serious emergency requiring a MAYDAY call, not to be thought of as an additional back up.
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,396
Likes: 0
Received 0 Likes
on
0 Posts
Perhaps you misunderstood his question. My Operator lists "Max FL for APU Battery Start" as FL250. -Both CEO & NEO. -note that's a battery start; which is what he was asking I believe
Join Date: Jun 2004
Location: Just Around The Corner
Posts: 1,395
Likes: 0
Received 0 Likes
on
0 Posts
In EM Electrical Conf each APU start attempt will drain the battery life , so the FL 250 i think is to wait for a level with dense air that will help the successful start .
I'm flabbergasted at the question on an APU battery start, the mention of battery starts itself means no other generator involved, the start is off the ships battery alone and each attempted start is going to drain the battery.
This is pretty basic stuff and any pilot who has been operating a descent turbo prop or jet should know this.
This is pretty basic stuff and any pilot who has been operating a descent turbo prop or jet should know this.
I'm flabbergasted at the question on an APU battery start, the mention of battery starts itself means no other generator involved, the start is off the ships battery alone and each attempted start is going to drain the battery.
This is pretty basic stuff and any pilot who has been operating a descent turbo prop or jet should know this.
This is pretty basic stuff and any pilot who has been operating a descent turbo prop or jet should know this.
Is the question being asked by a pilot or just an interested party?
So if the APU runs with constant RPM how does the geny lose power with altitude?
If the gen is 'on load' then it needs a finite amount of power to drive it at a constant rpm, if you increase altitude you will get to the point where the required demand load on the gen is too much for the reducing available power from the gas turbine. The APU will begin to slow down and once the frequency drops off below its limit, EG 398Hz, then the APU gen breaker will trip leaving you on battery power only until the RAT comes on line.
Join Date: Mar 2000
Location: Sunrise Senior Living
Posts: 1,338
Likes: 0
Received 0 Likes
on
0 Posts
Folks, the APU starts from the DC BAT Bus which is not powered in EMER ELEC - unless the APU Master is pressed. So, as someone has said above, every APU start in the A320 CEO is from the batteries. I have no knowledge of other variants.
cheers
mcdhu
cheers
mcdhu
I assume you are a non pilot. When you ask a generator to produce electricity it requires power to do so. 500 HP can produce a lot more power than 5 HP. A gas turbine loses about half it’s available power from sea level to 20,000 feet. At some point in a climb the available power usually becomes less than the rated output of the generator. You must reduces electrical output at that point or the gas turbine will either overtemp or be unable to maintain the required RPM resulting in the generator frequency output falling below limits.