found MD11 main landing gear extention and retraction actuator hyd leek at the seal and retainer,not obviously,but in one hour a drop will come out.Could some one tell me does it matter,what should i do?
Thanks.
freezingbore is offline  
Old 23rd Mar 2009, 11:59
  #2 (permalink)  
 
Join Date: Feb 2008
Location: europe
Posts: 33
Likes: 0
Received 0 Likes on 0 Posts
One drop an hour is not a big deal, as the amm will tell you.
Insert the gear pins (ALL of them please!) and select the gear up hydraulically, you will quite likely have a large increase in leak rate...

Remember this actuator is pressurized the entire flight (well as long as the gear is up).
The actuator has a spare seal, but swapping it out can be a handfull as the torque on the retainer is REALLY high.
Replacing the actuator at homebase will be the way to go, if current leak rate allows it to be scheduled.

The actuator is a heavy thing and at least a bucket and a half of skydroll will be headed your way after disconnecting.

Be safe, IFIX
IFIX is offline  
Old 23rd Mar 2009, 13:37
  #3 (permalink)  
Thread Starter
 
Join Date: Jan 2009
Location: China
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
Thank you,IFIX
freezingbore is offline  
Old 29th Mar 2009, 07:30
  #4 (permalink)  
 
Join Date: May 2001
Location: Mumbai, INDIA
Posts: 445
Likes: 0
Received 0 Likes on 0 Posts
One drop in 60 secs seems within limits but regular monitoring would be needed to identify an increase in leak or drop in qty.
The AMM will list the tolerences.

regds
MEL.
HAWK21M is offline  
Old 29th Mar 2009, 11:16
  #5 (permalink)  
 
Join Date: Jun 2007
Location: UK
Age: 70
Posts: 191
Likes: 0
Received 0 Likes on 0 Posts
Do not take advice from any-one on a public forum - read the AMM. Keep safe !
Terry McCassey is offline  
Old 29th Mar 2009, 14:58
  #6 (permalink)  
 
Join Date: Jan 2003
Location: Europe
Posts: 270
Likes: 0
Received 0 Likes on 0 Posts
Do not take advice from any-one on a public forum - read the AMM. Keep safe !
That is exactly what I was thinking.
DBate is offline  
Old 29th Mar 2009, 23:20
  #7 (permalink)  
Registered User **
 
Join Date: Mar 2009
Location: USA
Age: 49
Posts: 480
Likes: 0
Received 0 Likes on 0 Posts


That big cylinder on the gear that is leaking 1 drop per minute is actually the retract actuator, after the unlock cylinder "little one look up" locks the linkage over center the actuator has no significant pressure on it.

The upside to your delema is after you dump a hydraulic system gravity should lock the gear down so you can do an air turnback.

Wanna have some fun, pin the gear (all of them please), put the handle up and watch the actuator blow fliud all over the ramp.

Some of this is serious some humor, but all is for REFRENCE ONLY.

Last edited by muduckace; 29th Mar 2009 at 23:55.
muduckace is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Thread Tools
Search this Thread

Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.