10th Sep 2008, 17:13
Replies: 3,239
Views: 1,137,456
Posted By pax2908

Reading again ... could someone please clarify...

Reading again ... could someone please clarify the following (on Page 10 of the report): "approx 6500 to 7100 kg of fuel had leaked [] before the spar valves were manually closed". I thought these...
7th Sep 2008, 09:28
Replies: 3,239
Views: 1,137,456
Posted By pax2908

I still find it annoying that "fuel temperature"...

I still find it annoying that "fuel temperature" is actually just one sensor, in a relatively big system. The explanation given in the report, why the measured temperature is representative, is quite...
9th Aug 2008, 19:22
Replies: 3,239
Views: 1,137,456
Posted By pax2908

I apologize for yet another ignorant question...

I apologize for yet another ignorant question (please delete if inappropriate). To get the fuel out of the tanks, air has to go in... What happens if that vent is obstructed? (Can it?)
7th Aug 2008, 14:37
Replies: 3,239
Views: 1,137,456
Posted By pax2908

Re. Fullwings about the flow simulation...

Re. Fullwings about the flow simulation example...

I have learned (or was often reminded) that no simulation is really worth some real data. So what I would expect, if the situation is not clear...
23rd Jul 2008, 06:27
Replies: 3,239
Views: 1,137,456
Posted By pax2908

As I understand, one of the factors in this...

As I understand, one of the factors in this accident was that the problem was recognized late, with very little time to react. Would it be possible (reasonable?) to change the procedures so that this...
17th May 2008, 06:49
Replies: 3,239
Views: 1,137,456
Posted By pax2908

Location of temp sensor

How is it decided (apart from practical issues) where to install the sensor? Was the a/c once instrumented with tens of sensors in various places, then the worst case was chosen?
18th Mar 2008, 17:12
Replies: 3,239
Views: 1,137,456
Posted By pax2908

To Question 2: perhaps the output pressure would...

To Question 2: perhaps the output pressure would show fluctuations which (depending on the sample rate) could indicate that the pump is cavitating?
1st Mar 2008, 07:23
Replies: 3,239
Views: 1,137,456
Posted By pax2908

Re. software updates. Please allow a general...

Re. software updates. Please allow a general question: what is actually certified? Not really the a/c itself (after a s/w update, it is no longer the same a/c). How does the regulating authority...