26th Jun 2022, 19:44
Replies: 26
Views: 10,392
Posted By easymxp

The procedure to wait 1 minute idle, then 1...

The procedure to wait 1 minute idle, then 1 minute with bleed on and packs off and then all (or 1 pack) on is a company procedure. The 3 minutes idle instead is an airbus policy.
Forum: Tech Log
15th Jun 2022, 17:37
Replies: 26
Views: 10,392
Posted By easymxp

in my opinion having used the first procedure in...

in my opinion having used the first procedure in my first post (which is even more complicated than airbus 3 mins wait rule) and the new airline one with no delay rule.

3 mins procedure/ avail 1...
Forum: Tech Log
15th Jun 2022, 11:49
Replies: 26
Views: 10,392
Posted By easymxp

Here we used to do in order to vent any possible...

Here we used to do in order to vent any possible contamination in the bleed system…

I found a very long procedure as it required more time to start everything up, so delaying APU start to just...
Forum: Tech Log
14th Jun 2022, 12:18
Replies: 26
Views: 10,392
Posted By easymxp

APU start technique A320

Hello everyone,

my previous airline used this lenghty procedure for apu start on A32X family to avoid air/pack contamination events.
start apu, after avail wait one minute, then bleed on with...