Old 23rd Dec 2018, 02:38
  #41 (permalink)  
 
Join Date: Jan 2008
Location: Denver
Posts: 946
Originally Posted by fullforward View Post
What I’ve learned from a source directly involved in the incident, they were definitely on battery power alone at landing.
Interesting - but the phrase "at landing" is a bit ambiguous.

It is certainly true that a RAT, as the name says, runs off ram-air pressure (airspeed) and will need some minimum airspeed (130 knots in a 767) to produce useful output. So they would have lost the RAT power at some point in the final approach or roll-out, even if it was deployed and functioning for most of the event. And been on battery power alone from that point on.
pattern_is_full is online now  
Old 23rd Dec 2018, 04:07
  #42 (permalink)  
 
Join Date: Jul 2007
Location: the City by the Bay
Posts: 499
This should not have happened. Uncle Boeing is going to get more grey hair

armchairpilot94116 is offline  
Old 23rd Dec 2018, 08:33
  #43 (permalink)  
 
Join Date: Dec 2003
Location: Tring, UK
Posts: 1,364
It's been many years since I was involved in the 777 development, but IIRC, the RAT generator fed the battery bus directly - if they still had the battery bus they would have still had the RAT generator.
Looking at the FCOM, the RAT supplies the C1 & C2 TRUs, which power the capt & FO instruments and via them, the battery busses. I also see a note: “The main battery can power the standby system for a minimum of 10 minutes”, which isn’t much!

This should not have happened. Uncle Boeing is going to get more grey hair
I suppose there are two ways of looking at this: on one hand, that this shouldn’t have happened and is evidence of poor design (sorry td) but on the other, that after a once-in-a-hundred-million-flight-hours level failure(s), there was enough redundancy/backup in the system to allow the crew to make a successful approach and landing, which is indicative of a very good implementation. I think I would side with the latter...
FullWings is offline  
Old 23rd Dec 2018, 09:54
  #44 (permalink)  
 
Join Date: Oct 2012
Location: UK
Posts: 1,744
Originally Posted by FullWings View Post

there was enough redundancy/backup in the system to allow the crew to make a successful approach and landing, which is indicative of a very good implementation.
Hold on! They landed yes. But, there were probably some circumstances that made this possible and, others where it would not have ended so well. Those who operate similar aircraft will possibly get the full detail on this and learn something. The rest of us are probably not going to know that much. Would be good, when the truth is known, for someone in the real know to describe exactly what happened, please. In the meantime, I don't think anyone can make statements about how good/bad the systems performed here.

OAP
Onceapilot is offline  
Old 23rd Dec 2018, 10:20
  #45 (permalink)  
 
Join Date: Dec 2006
Location: Florida and wherever my laptop is
Posts: 1,274
Originally Posted by Onceapilot View Post
Hold on! They landed yes. But, there were probably some circumstances that made this possible and, others where it would not have ended so well. Those who operate similar aircraft will possibly get the full detail on this and learn something. The rest of us are probably not going to know that much. Would be good, when the truth is known, for someone in the real know to describe exactly what happened, please. In the meantime, I don't think anyone can make statements about how good/bad the systems performed here.

OAP
A lot depends on how far down the probability tails you want to proceed. In almost all FMEAs you get to conditions occur only where several highly improbables occur concurrently in a highly improbable sequence. It gets very difficult to persuade system developers to redesign systems to cope with probabilities in the 10^-15 range.
Ian W is offline  
Old 23rd Dec 2018, 12:04
  #46 (permalink)  
 
Join Date: Jul 2014
Location: Germany
Posts: 334
Notable incident of the 777 electrical system: United 777 on the Ground in London 2007 with a complete meltdown of a contactor
https://aviation-safety.net/database...?id=20070226-0


Also this diagram seems interesting:
wiedehopf is offline  
Old 23rd Dec 2018, 14:28
  #47 (permalink)  
 
Join Date: Apr 2009
Location: On the Beach
Posts: 3,197
Do I presume correctly that one IRU must have been powered for one attitude platform to be functional?
aterpster is offline  
Old 23rd Dec 2018, 14:37
  #48 (permalink)  
 
Join Date: Oct 2012
Location: UK
Posts: 1,744
Originally Posted by Ian W View Post
A lot depends on how far down the probability tails you want to proceed. In almost all FMEAs you get to conditions occur only where several highly improbables occur concurrently in a highly improbable sequence. It gets very difficult to persuade system developers to redesign systems to cope with probabilities in the 10^-15 range.
OK Ian! Yes, you are correct. However, for simple folk, like me, we work in a simple world where the faults in aircraft electrical power systems work something like this.... Short circuit in a system=CB Trip. Overload of a Busbar=Isolation or,=Auto load shedding (normally alternate systems avail on another Bus). T/R fail=Isolation (also, normally alt sys avail). Gen Fail= Isolation, (normally single Gen fail accommodated with alt source select and, no services lost). Multi Gen fails, protected by isolation of Busbars to protect partial remains of system with working generators and avoid overload. Batt fail, can be complicated but, generally systems work as long as engines/Generators working. etc...
Therefore, rather than talking mathematics, it would be great to know what failure mitigation worked or, didn't work in this case?
Cheers
OAP
Onceapilot is offline  
Old 23rd Dec 2018, 15:55
  #49 (permalink)  
 
Join Date: Jan 2004
Location: West Coast Canada
Posts: 3,452
Still a better design than Airbus were one grenaded engine in the QANTAS A380 took out 55 systems......
Big Pistons Forever is offline  
Old 23rd Dec 2018, 18:03
  #50 (permalink)  
 
Join Date: Dec 2000
Location: Nor-Cal
Posts: 5
LATAM B773

I not qualified on 777, but every Boeing I flew the anti-skid was AC powered.... These guys land Hot, Heavy, and no flat tires. Deflated due to heat not having the bottom worn off ;-)) Job well done.
SteveB1 is offline  
Old 23rd Dec 2018, 18:27
  #51 (permalink)  
 
Join Date: Sep 2011
Location: FL390
Posts: 289
Originally Posted by Big Pistons Forever View Post
Still a better design than Airbus were one grenaded engine in the QANTAS A380 took out 55 systems......
Did you see what the debris did to the wiring looms on that A380? This is entirely different - it's one tiny fault that should never, ever, have progressed any further than an EICAS advisory.

I think there will be some concerned engineers at Boeing over Christmas.

​​​​
Fursty Ferret is online now  
Old 23rd Dec 2018, 18:49
  #52 (permalink)  
 
Join Date: Aug 2007
Location: Brazil
Posts: 67
According to the commander, interviewed on TV, power came back after the engines were shut down. Presumably from the APU, on the footage the cabin lights were visible.
belfrybat is offline  
Old 23rd Dec 2018, 19:44
  #53 (permalink)  
 
Join Date: Jun 2002
Location: Southern Europe
Posts: 209
Originally Posted by tdracer View Post

DeeVee - again, a couple decades since I was involved, but based on what I remember, the only way they could have lost all main bus electrical power (with both engines running) would have been either:
latent failures in the electrical bus isolation system (there are regular maintenance checks to confirm such failures are not present),
Notable incident of the 777 electrical system: United 777 on the Ground in London 2007 with a complete meltdown of a contactor
https://aviation-safety.net/database...?id=20070226-0
Would speculate that we getting in the right track ...

AC Power is the "standard", or is prefered, for several systems in commercial air transport aircraft. Don't ask me why, as I don't know the reason ...

AC Power has however a big inconvenience. You can have 10 sources of good working AC Power available. However only 1 of those sources can supply power to an AC Bus at a time. You cannot connect them in Parallel, or in Series, like with DC Power.

If a contactor becomes stuck, for whatever reason, and doesn't "let go", to allow another source of AC Power to power the an AC Bus that is without power, then this kind of scenario can happen. Several sources of AC Power available, but none is allowed to supply power to AC Buses that are without power, because the contactor is stuck in position that allows only the Failed source to power the Bus, or it didn't shift completely to allow another source in.

AC Power ... we owe that to Tesla

Last edited by zerograv; 24th Dec 2018 at 15:26. Reason: not applicable info
zerograv is offline  
Old 23rd Dec 2018, 20:24
  #54 (permalink)  
 
Join Date: Oct 2012
Location: UK
Posts: 1,744
zerograv,
AC power generation and systems on aircraft are used for reasons of efficiency and weight. DC is needed for systems that require it and, is generally derived from Transformer rectifiers. Of course, the DC battery is usually used as a power source for starting a fully shut-down aircraft and, linked into the DC system, it can act as a limited power source in malfunctions. To back this up, there are usually Inverters to provide AC for certain equipment where/when it is not available from the normal AC Generators. AC power supplies on large aircraft can usually be paralleled and the AC system will normally be operated in parallel.
You are correct that "contactors" can have switching or latching failures. In fact, all components can fail. Where faults occur, it may be that a generator cannot be paralleled. These systems on large aircraft are quite complex but offer large resources of failure mitigation, which is why this apparently serious failure is important. Cheers

OAP
Onceapilot is offline  
Old 23rd Dec 2018, 21:34
  #55 (permalink)  
 
Join Date: Jan 2004
Location: West Coast Canada
Posts: 3,452
These systems on large aircraft are quite complex but offer large resources of failure mitigation, which is why this apparently serious failure is important. Cheers
Thinking about this some more, I bet when the full story is out inaction or inappropriate action by the crew contributed to the severity of this situation, like for instance the LOT 767 gear up. The 777 is a very mature design so I find it hard to believe that there is a fail mode that can kill everything.

There does appear to be a trend to minimizing the importance of system knowledge in modern training systems.

in any case however the crew got to a dark cockpit, they still did a very good job of getting the airplane on the ground with negligible damage.
Big Pistons Forever is offline  
Old 23rd Dec 2018, 23:38
  #56 (permalink)  
 
Join Date: Jun 2002
Location: Southern Europe
Posts: 209
Originally Posted by Onceapilot View Post
zerograv,
AC power generation and systems on aircraft are used for reasons of efficiency and weight.

OAP
Thanks for that !

To improve my concept of "paralleling", 2 generators can supply power to an AC BUS at same time ?
zerograv is offline  
Old 24th Dec 2018, 00:16
  #57 (permalink)  
 
Join Date: Feb 2018
Location: Canberra
Posts: 0
Originally Posted by zerograv View Post
To improve my concept of "paralleling", 2 generators can supply power to an AC BUS at same time ?
AC generators can most definitely share a load, and co-exist on the same "bus" or transmission medium.
The only requirement is that they are in sync, phase and frequency wise.

Pretty much exactly the same as how your home Solar Inverter feeds its energy back into the grid.

I would hope aircraft generators ran in sync, otherwise switching at an inopportune moment (like when one failed) might lead to smoke and noise......
Dee Vee is offline  
Old 24th Dec 2018, 00:18
  #58 (permalink)  
 
Join Date: Jul 2009
Location: USA
Age: 73
Posts: 98
Sorry for what may be a stupid question. I am a mechanical engineer so my EE skills went by eons ago in college and I have only worked with DC circuits on mobile equipment but the electrical grid has tens of thousands of generators powering it, all synced to the same frequency. In the old days they used primitive means to sync but putting a generator on line out of phase can negate the power so they must be synced. Is this not possible on an airplane?
NWA SLF is offline  
Old 24th Dec 2018, 00:51
  #59 (permalink)  
 
Join Date: Jul 2013
Location: Everett, WA
Age: 64
Posts: 2,335
The 777 can sync the AC buses when needed. For example, when you shutdown an engine, there is a light delay (250 ms if memory serves) before the fuel shutoff command goes to the engine. ELMS uses this delay to sync the AC bus before the engine spools down and the IDG drops off line (known as a 'breakless transfer'). So if everything is working correctly, on the 777 you don't get that annoying ~50 ms power interrupt when a generator comes on or drops off line that causes the displays to flicker on the 747-400/757/767/
tdracer is offline  
Old 24th Dec 2018, 02:23
  #60 (permalink)  
 
Join Date: Sep 2018
Location: Laredo, TX
Posts: 92
Phase lights

My memory is hazy but we synced the generators on the 727 using phase lights. If you rushed the sync you could get a little shudder in the A/C.
As part of my expansion of CV during the Arab Oil Emargo, where no flying gig was available, I did a stint in a nuclear/fossil power plant. They told a story of a many ton generator being twisted off mounts when somehow put online out of phase. Off topic sorry.