Go Back  PPRuNe Forums > PPRuNe Social > Jet Blast
Reload this Page >

Domestic water softener installation problems.

Jet Blast Topics that don't fit the other forums. Rules of Engagement apply.

Domestic water softener installation problems.

Old 1st Apr 2021, 22:17
  #1 (permalink)  
Ant
even ants need some lovin'
Thread Starter
 
Join Date: Jan 2001
Location: Kent, UK.
Posts: 147
Domestic water softener installation problems.

As an entirely predictable and inevitable result of not carrying out suitable checks and planning before I went ahead and bought an ion exchange water softener, I'm now appealing to the PPRuNe community to offer any suggestions and advice to overcome two tricky installation problems that have been encountered. Yes I know its my own silly fault!!
Even so, I would imagine these problems are probably typical of many such installations, and quite possibly other PPRuNers out there may have advice to offer based on their own personal experiences.

Problem 1.
The installation instructions require provision for two 15mm hoses to discharge to the exterior of the building. One is for the overflow of water in the event of the float valve failing, and the second is for discharge of brine during the periodic backwash of the resin ion exchange tank. The overflow is not a problem as it could safely be directed onto the path and lawn in front of the house, but pouring brine onto the lawn will quickly have dire consequences for the grass and nearby plants and so is not an option. It occurred to be to have the brine hose discharge into the waste pipe that the sink and dishwasher are connected to, but since the sink U-bend trap will be higher than the brine outflow spout (not allowed as the flow would be uphill) the alternative is to put the brine hose through a drilled hole in the pipe near to floor level with the result that the hose will have nothing to separate it from the foul gasses of the public waste water system. Would it be too optimistic to hope the brine would kill airborne bacteria settling and moving upwards in the hose? Another idea is to run the brine through a hose running along the side of the house to a back garden gully, a distance of 8 meters along which the speed of water might unfortunately be slow enough to form a plug when the pump stops at the end of the backwash cycle and the risk of that freezing inside the hose in wintertime.

Problem 2.
I had anticipated positioning the machine on the bottom shelf of the cupboard directly below our kitchen sink. However, the machine is too tall by 2 centimetres and the cupboard is not wide enough to put the machine to one side or other of the sink. The dishwasher occupies the space to the right and an expensive rotating basket storage contraption to the left, which in order to maintain marital domestic harmony can not be removed. The shelf I mentioned sits on legs 12 cm high and the side walls of the cupboard screw onto its sides. Would it be realistic to try somehow to remove just enough of that shelf in situ to keep the structural strength of the cupboard and at the same time allow the softener to slide in at floor level to fit neatly under the sink?

Should I just return the unit in disgrace, or is there hope yet?
Ant is offline  
Old 1st Apr 2021, 23:08
  #2 (permalink)  

Controversial, moi?
 
Join Date: Oct 2000
Location: UK
Posts: 1,596
Problem 1: Not unusual to have this sort of drainage problem.

My sister's softener is under sink in a utility room with the waste outlet from the softener discharging into a vertical pipe with a trap lower down the pipe. the problem was that if a sink full of water was emptied it would sometimes back up the softener stand pipe drain and overflow into the cupboard. I solved the problem by an arrangement similar to this crappy drawing:
To explain the drawing: I put a 40mm tee in the outlet from the sink and connected a P-trap to that tee piece. On the upright pipe connected to the trap I put another tee with a hose adapter to which I securely fastened the softener outlet with a jubilee clip. I extended the upright pipe and fitted an Air Admittance valve This allowed air in when the softener was discharging but prevented water from the sink backing up through the softener trap and, previously, overflowing from the softener fixed pipework. It works well. You will need to hunt around to find suitable fittings but they are all available.

Bear in mind a source of unsoftened water for drinking should be available. I dislike water softeners in cupboards under sinks purely due to the awkwardness of filling with salt. Unless you have purchased a block salt machine in which case you will pay an arm and a leg for the convenience of block salt. My softener is in my garage.

Problem 2: Providing the cupboard is well made and fitted I can see no problem in cutting out a suitable opening in the shelf to accommodate the softener. Care and planning would be needed to avoid making the cupboard look like it had been butchered!

Where in the UK are you based?
M.Mouse is offline  
Old 2nd Apr 2021, 06:14
  #3 (permalink)  
 
Join Date: Jul 2008
Location: Only occasionally above FL50
Age: 68
Posts: 135
The brine outlet from my under sink water softener rises and connects above the trap under the sink - as does the dishwasher. Both eject waste water under pressure so ‘going uphill’ is not a problem. Both have worked fine for 9 years.
Andrewgr2 is offline  
Old 2nd Apr 2021, 06:18
  #4 (permalink)  
 
Join Date: Aug 2015
Location: 5Y
Posts: 528
Originally Posted by Ant View Post
As an entirely predictable and inevitable result of not carrying out suitable checks and planning before I went ahead and bought an ion exchange water softener, I'm now appealing to the PPRuNe community to offer any suggestions and advice to overcome two tricky installation problems that have been encountered. Yes I know its my own silly fault!!
Preparation and planning take all the fun out of tasks like this!
double_barrel is online now  
Old 3rd Apr 2021, 20:53
  #5 (permalink)  
Ant
even ants need some lovin'
Thread Starter
 
Join Date: Jan 2001
Location: Kent, UK.
Posts: 147
A fine Cuban cigar for M.Mouse and his superior plumbing skills!!
Seeing that drawing makes total and complete sense, it seems so simple and logical doesn't it when someone has worked it all out for you!

I do take on board the comment from Andrewgr2 about an uphill flow under pressure from the pump being OK, as both our washing machine and dishwasher have worked for years with the wastewater going quite a ways uphill, but given that the water softeners installation manual said to ensure the hose exit is below the spout I thought it best to plan for that.

As for double_barrel saying that preparation and planning take all the fun out of tasks like this!
Well folks, I'll just say that mirth and merryment were in painfully short supply when the Camp Commandant (aka wife) was informed that her lovely kitchen which was renovated at considerable cost a few years back would have to undergo "some minor modifications" to accommodate the water softener which incidentally I had neglected to inform her had already been purchased.

And finally, I have a neighbour to thank for suggesting I borrow a jig saw to make the cupboard modifications, rather than the electric chain saw I have that I had at one point considered!
Chain saws and renovated kitchens do not sit easily together, and would test the strongest marriage.
Ant is offline  
Old 3rd Apr 2021, 23:13
  #6 (permalink)  
 
Join Date: Dec 2005
Location: Elsewhere
Posts: 259
I thought about a water softener, had similar thoughts about making it work, then took the easy option,

I moved to Devon!

In the four years since we moved here I haven't had to descale the kettle once.
k3k3 is offline  
Old 4th Apr 2021, 12:02
  #7 (permalink)  
I don't own this space under my name. I should have leased it while I still could
 
Join Date: Dec 2002
Location: Lincolnshire
Age: 77
Posts: 16,744
MMs solution is what we had. Slightly simpler, the outlet hose was simply hooked over the outlet pipe, same as unplumbed washing machines.
Pontius Navigator is offline  
Old 4th Apr 2021, 14:06
  #8 (permalink)  

Controversial, moi?
 
Join Date: Oct 2000
Location: UK
Posts: 1,596
Slightly simpler, the outlet hose was simply hooked over the outlet pipe, same as unplumbed washing machines.
That will often work. In my sister's case when the washing machine emptied the long path the drain took to outside was too slow and on occassions the water softener drain standpipe would back up and overflow into the cupboard, hence the solution illustrated.
M.Mouse is offline  
Old 5th Apr 2021, 13:50
  #9 (permalink)  
 
Join Date: Feb 2000
Location: UK
Posts: 1,428
Your neighbour's suggestion of jigsaw for the 'operation' may well be ideal, if you own one already. If not, it is a good reason (excuse) for buying an even more useful 'multi tool' - the vibrating device with interchangeable heads. Not only easier to use, but no 'starter hole' needed and the finish is superior. No 'Boy's Toys' cupboard ahould be without one !
Cornish Jack is offline  
Old 5th Apr 2021, 21:56
  #10 (permalink)  
 
Join Date: Apr 2008
Location: Out in the sticks in DE56
Age: 82
Posts: 554
Originally Posted by Cornish Jack View Post
Your neighbour's suggestion of jigsaw for the 'operation' may well be ideal, if you own one already. If not, it is a good reason (excuse) for buying an even more useful 'multi tool' - the vibrating device with interchangeable heads. Not only easier to use, but no 'starter hole' needed and the finish is superior. No 'Boy's Toys' cupboard ahould be without one !
Just what I would have said last night, but just doing a quick read-in; no time.
The multi-tool is a fantastic little bit of kit. And last year's Christmas present of a 10mm belt sander is the other toy I've found endless uses for already.
jimtherev is offline  
Old 5th Apr 2021, 22:09
  #11 (permalink)  
 
Join Date: Jul 2014
Location: Surrey
Age: 63
Posts: 176
Why do you sand your belts - are they not smooth leather ?...............................Ah,the penny's dropped !
ex82watcher is offline  
Old 5th Apr 2021, 22:20
  #12 (permalink)  
 
Join Date: Jul 2014
Location: Surrey
Age: 63
Posts: 176
Originally Posted by k3k3 View Post
I thought about a water softener, had similar thoughts about making it work, then took the easy option,

I moved to Devon!

In the four years since we moved here I haven't had to descale the kettle once.
When I moved into this house 30+ years ago,I fitted a 'Lif Limefighter' directly above the rising main.This is just a plastic tube containing a ceramic magnet,with a compression fitting at each end.It cost less than £20, and took about 10 minutes to fit.Despite having hard water here,I don't have to descale the kettle,and my washing machine is now 26 years old,and I've never added anything such as Calgon to prevent scale.
ex82watcher is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On