SAAB Manual AMM 76-10 CTOT torque fault finding
Sheet 1 - FIGURE 76-10-00-990-827-1 Fig. 101 CTOT System - Fault Isolation Page 1 of 2
the SAAB manual has an error on here stating the base voltage is 5.042 VDC +/- 10%....this 10% is incorrect and should read +/- 10mv...
yes a correction was submitted to SAAB but they are as interested in correcting their documentation as the Australian government is in building a real NBN.