PPRuNe Forums - View Single Post - AF447
Thread: AF447
View Single Post
Old 30th Jun 2009, 13:14
  #2550 (permalink)  
augustusjeremy
 
Join Date: Jun 2009
Location: Somewhere out there
Age: 39
Posts: 65
Likes: 0
Received 0 Likes on 0 Posts
egg and chicken again - who/what/which came first ?

0209 START
0210 34-11-15-0 FLR EFCS2
EFCS1, AFS - PROBE PITOT 1+2/2+3/1+3 (9DA)
9DA=HEATING ELEMENT PITOT 1 (6DA1/PHC1)
Heating Element Pitot 1 suspected failed.


0210 27-93-34-0 FLR EFCS1
EFCS2-FCPC2(2CE2) WRG:ADIRU1 BUS ADR1-2 TO FCPC2
No Data from ADIRU 1, ADR 1 & 2 no sending signal to FCPC2
No ADR Data from ADIRU 1 to PRIM2.
Someone came with the answer to my question at last.
Thank you !!!

From flight qantas 72 interim report:

Probe heat computer
Some of the PFR messages indicated a potential fault with the number-1 probe heat
computer (PHC). Those messages could be generated by either a PHC fault or by an
ADIRU fault. The PHC (serial number 2083) was tested by an authorised agency
and no fault was found. Based on a review of available information, the messages
related to the PHC were considered to be spurious.
augustusjeremy is offline