Originally Posted by
Connie Wings
How is the messages inhibition logic during takeoff phase ?
The FIRE message is still displayed on EICAS, but the master warning lights and bell are inhibited from V1 (or rotation, whichever occurs first) until 400 ft RA or 25 seconds after the inhibit began, whichever occurs first.