selfin 3rd Nov 2007 18:07

PA44 electrical system
 
Can someone who is familiar with the Seminole electrical system explain why there is a 25 A BTB between the AVI buses?
http://img162.imageshack.us/img162/9...lectky2.th.jpg
(Click the thumbnail to see a large diagram of the electrical system.)

Dysonsphere 3rd Nov 2007 18:29

looking at it as a sparks i would imanige it is there to cross power the AVI stacks

selfin 3rd Nov 2007 21:20

Hardly when the 40 A breaker trips... is it only to protect against a relay failure? Other than this I can't really see the benefit.

L-Band 4th Nov 2007 07:09

It is there in case of a avionics bus relay failure to make sure you do not lose both sides of the avionics bus.

L

selfin 4th Nov 2007 14:09

Thanks for the clarification.

BRL 4th Nov 2007 14:18

Hi Selfin, I moved this here after a day or so as you were not getting much views in the other forum. :)

Short_Circuit 4th Nov 2007 20:49

It is there to stop a short on one bus taking out both busses i.e. both nav / com would otherwise die. Not ideal situstion for just one unit turning to toast.