A320 CAT 3 single only with no ECAM

Hello folks,

The other day shortly after takeoff we had status displaying cat 3 single only without any prior ECAM caution. It remained like this for the whole flight till after landing when it disappeared. My idea is that it could be related to the failure of the electrical power supply split as you need it only for cat 3 dual but I remember also that there is another failure leading you to the same status, I think it's described in the FCTM but I can't seem to locate it. Any thoughts ?

Cheers.

Last edited by sonicbum; 14th Jun 2015 at 06:47. Reason: P.s. Yes both fmgc were operative ;-)
sonicbum is offline  
Old 14th Jun 2015, 08:14
  #2 (permalink)  
 
Join Date: Mar 2006
Location: AUSTRALIA - CHINA STHN
Age: 59
Posts: 261
Likes: 0
Received 0 Likes on 0 Posts
Guessing but...

Might be an internal IR issue.in the 330 this sometimes happens with no ECAM ... Because there is nothing you can do. It simply changes the aircraft status for autoland... Could be something else entirely of course ... Airbus n all....
woodja51 is offline  
Old 14th Jun 2015, 08:31
  #3 (permalink)  
 
Join Date: Mar 2000
Location: Sunrise Senior Living
Posts: 1,338
Likes: 0
Received 0 Likes on 0 Posts
We used to get this in some older 320s I used to fly some years ago. Swapping APs in the cruise used to fix it.
mcdhu is offline  
Old 14th Jun 2015, 08:35
  #4 (permalink)  
Thread Starter
 
Join Date: Mar 2012
Location: Having a margarita on the beach
Posts: 2,420
Likes: 0
Received 0 Likes on 0 Posts
Thanks for you answersWe tried to switch APs but no results.
sonicbum is offline  
Old 14th Jun 2015, 08:55
  #5 (permalink)  
 
Join Date: Aug 2012
Location: United Kingdom
Age: 34
Posts: 948
Likes: 0
Received 0 Likes on 0 Posts
We had this as well... very strange.
Skornogr4phy is offline  
Old 14th Jun 2015, 14:41
  #6 (permalink)  
 
Join Date: May 2012
Location: Cairo, Egypt
Posts: 36
Likes: 0
Received 0 Likes on 0 Posts
In the FCOM, Under PRO-SUP-22-10-C "Other abnormal procedures", it says that "CAT 3 DUAL" can be recovered by changing autopilots. If it does not work, recycle the FACs.

Doesn't include all MSNs though.
100 above minimums is offline  
Old 14th Jun 2015, 15:00
  #7 (permalink)  
 
Join Date: Mar 2007
Location: Here and there
Posts: 2,781
Likes: 0
Received 1 Like on 1 Post
I have posted about this before as we used to see it in old A320s. On the status page would be a message about Cat 3 Dual inop with no warning message. I remember it was something to do with AoA disagreeing.
tubby linton is offline  
Old 14th Jun 2015, 15:12
  #8 (permalink)  
Thread Starter
 
Join Date: Mar 2012
Location: Having a margarita on the beach
Posts: 2,420
Likes: 0
Received 0 Likes on 0 Posts
From the FCTM

ONE ADR OUTPUT IS ERRONEOUS AND THE TWO REMAINING ARE CORRECT
The ELAC and the FAC and/or FMGC eliminate the erroneous ADR. There is no cockpit effect (no caution, normal operation is continued), except that one display is wrong and the autoland capability is downgraded to CAT 3 SINGLE.

What do you think ? Might be the case for ADR 3 ? Both PFD were consistent...
sonicbum is offline  
Old 15th Jun 2015, 09:13
  #9 (permalink)  
 
Join Date: Sep 2012
Location: Nowhere near Shinbone Waterhole
Posts: 201
Likes: 0
Received 0 Likes on 0 Posts
I once checked the AoA during once such encounter Tubby and they were within a tight bull's roar of each other. I think the event may be caused electrically although I'd give consideration to ADR as per FCOM.
mikedreamer787 is offline  
Old 16th Jun 2015, 00:40
  #10 (permalink)  
 
Join Date: Aug 2007
Location: Middle East
Posts: 93
Likes: 0
Received 0 Likes on 0 Posts
According to memory:
One AOA is voted out and computer is using two AOAs.
The faulty AOA could be any one (1,2 or 3). If the faulty AOA is number 1 or 2 then you will not be able to tell which one is faulty as both PFDs will have normal display.
you can find out the value of AOA 1 or 2 using Mcdu but cannot find AOA 3 unless transferring IR 3 to side 1 or 2 then using the bird to determine AOA 3.

In the unlikely event of the other two AOAs bieng consistent but erroneous, then there will be a problem. In this case apply OEB (can not remember the number) which tells to switch off 2 ADRs
Rocket3837 is offline  
Old 16th Jun 2015, 02:42
  #11 (permalink)  
 
Join Date: Mar 2001
Location: I wouldn't know.
Posts: 4,497
Likes: 0
Received 0 Likes on 0 Posts
You can check the value of AOA 3 via the MCDU (AIDS). But checking the AOA values doesn't tell you if one of them is voted out due to an earlier glitch.
Denti is offline  
Old 16th Jun 2015, 05:09
  #12 (permalink)  
PPRuNe supporter
 
Join Date: Dec 2003
Location: Planet Earth
Posts: 1,677
Likes: 0
Received 0 Likes on 0 Posts
FAC 1 off, then on, FAC 2 off then, this used to take care of the problem.
Dream Land is offline  
Old 16th Jun 2015, 07:50
  #13 (permalink)  
Thread Starter
 
Join Date: Mar 2012
Location: Having a margarita on the beach
Posts: 2,420
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by Rocket3837
If the faulty AOA is number 1 or 2 then you will not be able to tell which one is faulty as both PFDs will have normal display.
Hi Rocket, I think I'm missing a point here. Let's say that AOA 1 is giving erroneous outputs, you won't notice anything on the PFD and the output will be automatically replaced by AOA 3 ?
Thanks
sonicbum is offline  
Old 18th Jun 2015, 00:05
  #14 (permalink)  
 
Join Date: Mar 2013
Location: Vice city
Posts: 13
Likes: 0
Received 0 Likes on 0 Posts
Had the same a couple of weeks ago. Probably rejection of one ADR without warning. We had the same due to a TAT birdstrike which resulted in rejection of ADR 2 due wrong data (TAS, W/V readout and computations)

Once on the ground the cat 3 single status message was gone because the a/c is not sensing airflow anymore so data was correct again and ADR was back in the loop. Worth while crosschecking all the pdf/nd values for all adrs
The bird is offline  
Old 18th Jun 2015, 10:32
  #15 (permalink)  
Thread Starter
 
Join Date: Mar 2012
Location: Having a margarita on the beach
Posts: 2,420
Likes: 0
Received 0 Likes on 0 Posts
Hi Bird,

following the rejection did you still have the erroneous data displayed ?
sonicbum is offline  
Old 18th Jun 2015, 15:55
  #16 (permalink)  
 
Join Date: Mar 2013
Location: Vice city
Posts: 13
Likes: 0
Received 0 Likes on 0 Posts
Yes it unless we switched F/O to adr 3. But for ldg capability the data was rejected. Ecam status clean after ldg during taxi in
The bird is offline  
Old 18th Jun 2015, 21:32
  #17 (permalink)  
 
Join Date: Jul 2006
Location: Depends
Posts: 11
Likes: 0
Received 0 Likes on 0 Posts
Had this occur to us in the past, and as in "The Bird" case it was due to a ADR being rejected after some moderate turbulence. Had us perplexed as well until the engineer on arrival told us it was due to one of the ADR's being rejected by the other two.
Out there is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.