Old 30th May 2007, 06:01
  #1 (permalink)  
Thread Starter
 
Join Date: Feb 2001
Location: Sometimes here, sometimes there
Posts: 440
Received 6 Likes on 3 Posts
Offshore Helideck Integrity

I'm investigating an occurrence and would like to get a feel for how widespread a problem it is.
Has anyone ever heard any tales or personally witnessed bits of helidecks coming loose as an aircraft was attempting to land on it? Did it strike the aircraft? If so, any damage worth speaking about?
I'm not really interested in general FOD, snow, plastic bags or anything else that shouldn't be on the helideck in the first place.
Thanks guys......
Variable Load is offline  
Old 30th May 2007, 07:24
  #2 (permalink)  
 
Join Date: May 2007
Location: back of beyond
Posts: 13
Likes: 0
Received 0 Likes on 0 Posts
Offshore Helideck Integrity

Over the years, we have experienced problems with equipment and stored scaffolding (read plywood) being blown around and overboard by the rotorwash, but the decks themselves have always held up. We have seen some pretty corroded safety nets and support structure. but they've always stayed put. I'll check around
360andoutofhere is offline  
Old 30th May 2007, 07:38
  #3 (permalink)  
 
Join Date: Aug 2003
Location: In my house
Posts: 320
Likes: 0
Received 0 Likes on 0 Posts
Variable Load

In nearly 30 years in the offshore helicopter industry, I haven't heard of integrity issues with the decks themselves.

Most oil companies and rig operators who own facilities with helidecks do or should have annual audits carried out which check deck integrity along with several pages of other items.

The worldwide standard for auditing a helideck is generally the excellent UK CAA CAP437 and most checklists over the years have been constructed using 437 as a reference.
Hippolite is offline  
Old 30th May 2007, 07:45
  #4 (permalink)  
cpt
 
Join Date: Dec 2002
Location: 1500' AMSL
Age: 67
Posts: 412
Received 1 Like on 1 Post
I know the case (a long time ago) where the corroded trap-door of an old helideck hatch, collapsed under the pressure of an Alouette 3 main gear wheel. The helicopter capsized an was written off.
I also remember a "welcome aboard" aluminium panel sign, flying off in a landing SA 330 damaging its tail rotor blades....
And many other various incidents alike (i.e empty drums rolling overboard in rotor downwash, torn windsock....)
cpt is offline  
Old 30th May 2007, 07:56
  #5 (permalink)  
 
Join Date: May 2007
Location: back of beyond
Posts: 13
Likes: 0
Received 0 Likes on 0 Posts
Helideck inspection checklist

OGP has a good checklist based on CAP 437 which is downlaodable at ogp.org.uk/publications/. Not much good for your problem now, but might be a help in the future.
360andoutofhere is offline  
Old 30th May 2007, 08:46
  #6 (permalink)  
 
Join Date: Apr 2002
Location: Aberdeen
Age: 51
Posts: 175
Likes: 0
Received 2 Likes on 2 Posts
I've seen a part of the helideck lighting come loose and luckily blow away from the aircraft.
Woolf is offline  
Old 30th May 2007, 08:57
  #7 (permalink)  
 
Join Date: Mar 2005
Location: Kammbronn
Posts: 2,122
Received 3 Likes on 3 Posts
From the perspective of an offshore resident, our Planned Maintenance System requires regular inspections of fixtures and fittings both on and in the vicinity of the helideck. The HLO also carries out a FOD check as well as a visual inspection of the net prior to operations, and as has already been mentioned, the whole sphere of helicopter operations is subject to a periodic audit.

I've no doubt that should a crew have any concerns about the integrity of our helideck, we'd hear about it in short order, and we have a vested interest in maintaining our primary means of getting off.
diginagain is offline  
Old 30th May 2007, 12:29
  #8 (permalink)  
Thread Starter
 
Join Date: Feb 2001
Location: Sometimes here, sometimes there
Posts: 440
Received 6 Likes on 3 Posts
Thanks for all the responses so far.

We do use CAP437 as the basis for our helideck design, inspections, etc.

The incident we had was with a deck that is designed to be removable by crane and has removable panels as part of the helideck top surface. The panels ended up being a bit too portable, but thankfully only enough to give the crew a fright.


The SMS follow up and risk assessment calls for the frequency of similar events in the industry to be established, hence the question........
Variable Load is offline  
Old 30th May 2007, 13:44
  #9 (permalink)  
 
Join Date: Oct 2006
Location: Kalifornica
Posts: 11
Likes: 0
Received 0 Likes on 0 Posts
Skirting Failure

I've seen pieces of the skirting flapping in my downwash, and been almost nervous enough about it to just fly away. The skirting in this case was corrugated metal. Other platforms I've seen use cyclone fencing material. If that piece had broken loose, and recirculated through the disk, we could have sustained significant blade damage.

Was transporting MMS inspectors to the platform ( GOM ). They wrote the operator up for that, and many other discrepancies on the platform.

HeloBeez
HeloBeez is offline  
Old 30th May 2007, 23:12
  #10 (permalink)  
 
Join Date: Aug 2001
Location: Cornwall
Age: 75
Posts: 1,307
Likes: 0
Received 0 Likes on 0 Posts
Thumbs up Helidecks

Variable
I've inspected a few hundred helidecks in my time in different parts of the world but have yet to come across a 'sectionalised helideck', presumeably with removeable deck plates.
Not sure to what standard it was built to but it certainly doesn't sound like it meets the requirements of either the ICAO Heliport Manual, or, for that matter CAP 437. It doesn't look like the authors of these documents have contemplated a 'loose plated deck' so one cannot say that it is "Non Compliant" but somewhere along the line there has been a goof-up because the risk assessment conducted at the design stage should have considered the 'worst-case' downwash effects.
Under JARs the helicopter operator (NOT the rig operator) is responsible for ensuring that the landing areas meets with the Helicopter Operators standards as set out in either their Vol A or Vol B or possibly their Vol C. If there is a problem then liability falls upon the helicopter operator and not the rig operator. Thats why all North Sea companies have a method for at least an annual inspection of helideck facilities.
Outside the highly regulated world of Europe there can be found a motley collection of rules and regs with a similarly motley standards of regulatory oversite. My advice is 'user beware' and if you don't like it then advise the owner that ops are suspended until the problem is fixed. After any incident you will be deafened by the noise of escaping stakeholders and the slowest, most exposed and least powerful/influential party will have the Donkey's Tail pinned to their backside.
For your SMS risk assessment you will just have to accept that there will be little or no other data available if the deck design is unique or nearly so. For this platform the event has already occured so the probability of it happening again on that rig is going to be high unless changes are made. If the platform is an 'import' has such an event occurrred elsewhere?
Rgds
G
Geoffersincornwall is offline  
Old 31st May 2007, 10:13
  #11 (permalink)  
 
Join Date: May 2007
Location: back of beyond
Posts: 13
Likes: 0
Received 0 Likes on 0 Posts
More on helidecks

Apropos of what G has pointed out in the above post, AMC No 2 to JAR OPS 3.220, Authorization of Heliports by the Operator-Helidecks, states that Part C of the Operations Manual in the Helideck Limitation List will show "the most recent status of each helideck concerning non-compliance with ICAO Annex 14 Volume 2, limitations, warnings, cautions or other comments of operational importance". This is tacit acknowledgement by the powers that be that not all helidecks are created equal and that the Operator can decide if the deck in question is safe to land on. They don't have to be perfect, but they shouldn't be falling apart!
360andoutofhere is offline  
Old 31st May 2007, 12:43
  #12 (permalink)  
Thread Starter
 
Join Date: Feb 2001
Location: Sometimes here, sometimes there
Posts: 440
Received 6 Likes on 3 Posts
G & 360

Sorry guys, I've got to reign in your enthusiasm here. As previously stated the helideck is fully compliant with the requirements of CAP437 and therefore ICAO Annex 14. The deck is also not "falling apart"!


Our operation has about five landings per flight hour so the concept of the design is well proven and not in question. This is the first such incident in many, many years of operation.


It's not appropriate for me to discuss here why the panel detached as the investigation is ongoing.


Now hopefully we can return back to my original question........
Variable Load is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.