Go Back  PPRuNe Forums > Misc. Forums > Passengers & SLF (Self Loading Freight)
Reload this Page >

How cold do parked aircraft get and can that cause damage?

Wikiposts
Search
Passengers & SLF (Self Loading Freight) If you are regularly a passenger on any airline then why not post your questions here?

How cold do parked aircraft get and can that cause damage?

Thread Tools
 
Search this Thread
 
Old 27th Mar 2017, 22:25
  #1 (permalink)  
Everything is under control.
Thread Starter
 
Join Date: Jul 2001
Location: Washington, D.C.
Posts: 435
Likes: 0
Received 0 Likes on 0 Posts
How cold do parked aircraft get and can that cause damage?

I'm sorry if I'm not using the right terminology. I'm thinking of an aircraft that's in service but parked at an airport overnight. If it's very cold it can get below freezing in the aircraft, which could freeze and burst water pipes. Or, are aircraft in those conditions kept warm so that doesn't happen? Just curious.
Eboy is offline  
Old 28th Mar 2017, 07:56
  #2 (permalink)  
 
Join Date: Sep 2012
Location: North of Watford, South of Watford Gap
Age: 68
Posts: 251
Likes: 0
Received 2 Likes on 1 Post
The air temperature at cruising altitudes will be far colder than anything on the ground, although obviously in the latter case the engines would supply heat. The fuselage has some insulation, so unless an aircraft was left parked for several days in the Alaskan winter I doubt whether the cold would cause too many problems.
Innominate is offline  
Old 28th Mar 2017, 08:16
  #3 (permalink)  
 
Join Date: Feb 2001
Location: The Winchester
Posts: 6,548
Received 5 Likes on 5 Posts
Most aircraft manuals (either flight crew and/or engineering ) will somewhere contain a procedure usually done by maintainance personnel for draining of potable water tanks and lines etc, in the event it is known the aircraft is going to be left unattended for a considerable length of time in very cold conditions....in my experience that is generally not done for a night stop unless it is really really cold....the cheaper option then is probably to use an external heat source to keep the internaltemperatures at a reasonable level.
wiggy is offline  
Old 28th Mar 2017, 08:46
  #4 (permalink)  
 
Join Date: Sep 2010
Location: UK
Posts: 889
Likes: 0
Received 1 Like on 1 Post
There was an interesting segment of the BBC2 series City in The Sky showing how they protect aircraft from extreme cold in Russia.

I'm sure someone on here will be able to provide the link.
vctenderness is offline  
Old 28th Mar 2017, 08:50
  #5 (permalink)  
 
Join Date: May 2009
Location: Confoederatio Helvetica
Age: 68
Posts: 2,847
Likes: 0
Received 0 Likes on 0 Posts
In the days of piston engines ground crews in Northern Canada would often have to pre-heat the engines using blow torches. Pesky things don't work with frozen oil.

See if you can find the thread in R&N/s about LX's diversion to Iqualit. That was an issue!
ExXB is offline  
Old 28th Mar 2017, 09:17
  #6 (permalink)  
 
Join Date: Dec 2004
Location: Andalucia
Posts: 728
Received 0 Likes on 0 Posts
A/c can and do freeze in a cold soak condition on the ground. Normal practice is to drain the Potable water system if a cold soak is forecast.
The pipework outside the conditioned area is heated in the air to maintain it above freezing. (Airbus certainly,dunno Boeing)

In days of yore the Comet used to freeze for England.
Wodrick is offline  
Old 28th Mar 2017, 18:07
  #7 (permalink)  
 
Join Date: Apr 2005
Location: Stockholm Sweden
Age: 74
Posts: 569
Likes: 0
Received 0 Likes on 0 Posts
Here in Stockholm it gets below minus 10 deg C regularly. All aircraft that are left outside unattended have the water system drained. We drain ours when the forecast is Minus 5degC or lower.
But aircraft that are parked on the F pier or Terminal 2, can have conditioned air supplied continuosly, and in that case the water is not drained.
One night a B737 had the heater hose fall off, and was not noticed. The tank froze and we had to park the aircraft in the SAS hangar for 8 hours to defreeze it!
Swedish Steve is offline  
Old 28th Mar 2017, 18:40
  #8 (permalink)  
 
Join Date: Aug 2000
Location: uk
Posts: 1,774
Received 19 Likes on 10 Posts
In days of yore the Comet used to freeze for England.
One of my instructors, also in days of yore, used to fly the Comet 3 at Boscombe Down. He regularly flew to Northern Canada and leave the aircraft to cold soak for a period. After the cold soak, they had to start up and be in the air with all systems working within a certain time. They then flew down to New Mexico and repeated the exercise after a hot soak.
pulse1 is offline  
Old 28th Mar 2017, 18:41
  #9 (permalink)  
 
Join Date: Feb 2006
Location: Hanging off the end of a thread
Posts: 32,757
Received 2,742 Likes on 1,168 Posts
Piston engines on large aircraft also used fuel dilution of the oil where petrol was used to thin it out, the fuel boiling off as it warmed up, also they had what was called a hot pot in the oil tank, this was like a cylindrical colander and the return warm oil would enter one end and the engine supply left the other end, this enabled a portion of the oil to heat up quickly and supply the engine, as it warmed up the heat would radiate out into the tank and the rest of the oil would then flow through the holes of the colander and be available to the engine.

As for jets, I did an engine change outside on the pan in Gander Newfoundland at -15, it dropped to well below that at night, bottle water in the galley had all blown and the caps were frozen on stalks of water as it pushed out of the bottles. We had to leave all the connections slightly loose as in those temps it was easy to break something, then once it was running and got some heat through it we went round and tightened up all of the connections. We then pressurised the cabin with the door partially cracked open to get some heat through the cabin. The aircraft had been sitting outside for four days like that. We then flew back in it that day. Ohh and yes it was cold.
NutLoose is online now  
Old 29th Mar 2017, 14:49
  #10 (permalink)  
 
Join Date: Mar 2001
Location: I wouldn't know.
Posts: 4,497
Likes: 0
Received 0 Likes on 0 Posts
Draining potable water is normal procedure on our planes here in germany in winter. Kinda dangerous during the walkaround next morning on the huge ice patch below the tail of the plane...
Denti is offline  
Old 29th Mar 2017, 17:05
  #11 (permalink)  
 
Join Date: Jun 2007
Location: Beyond the Blue Horizon
Age: 63
Posts: 1,251
Received 147 Likes on 91 Posts
Back in the 90,s I had a job in Edinburgh and was a regular on the Short 360 out of LBA - forget the carrier but I am sure someone will be along to remind me (Gill Airway's anyone, just remembered !). I also had few times in winter on the 06.30 depp where there was heavy frost on the ground, and the A/C was like an ice box (despite air blowers being used), you did not seem to get any warmth until abeam Carlisle ! Flying in colder climates which I have also done my fare share of, the carriers always seem to pre heat A/C but Gill Airways and LBA obviously did not always factor in the vagrancies of UK weather some mornings, well that's what it felt like anyway.

Last edited by Mr Mac; 29th Mar 2017 at 19:45.
Mr Mac is offline  
Old 29th Mar 2017, 18:02
  #12 (permalink)  
 
Join Date: Dec 2004
Location: Andalucia
Posts: 728
Received 0 Likes on 0 Posts
Draining potable water is normal procedure on our planes here in germany in winter. Kinda dangerous during the walkaround next morning on the huge ice patch below the tail of the plane...
Years and years ago, maybe 20, that practice was banned at Manchester and we had to drain into a tank.

Towards the end of my career, in Maintrol, there was a succession of phone calls from the outstations,every night when a frost was forecast "do you want it draining tonight ?" Buggered if you did, buggered if you didn't
Wodrick is offline  
Old 29th Mar 2017, 20:22
  #13 (permalink)  
Paxing All Over The World
 
Join Date: May 2001
Location: Hertfordshire, UK.
Age: 67
Posts: 10,143
Received 62 Likes on 50 Posts
I recall a (horribly) early start out of LHR in winter a few years back. The FC said that we had to spend a couple of minutes in the run up bay near the end of taxi way, before turning onto the active. They said, as first operation of the day and the cold night, they needed to give the engines longer to stablise. Otherwise, early starts are unremarkable - from the pax perspective.
PAXboy is offline  
Old 29th Mar 2017, 21:08
  #14 (permalink)  
 
Join Date: Jun 2002
Location: Wor Yerm
Age: 68
Posts: 4
Likes: 0
Received 0 Likes on 0 Posts
Eboy - Water is one of the things that can cause an aircraft damage when parking overnight. We solve that by dumping the remaining water before we land. Later on, when the aircraft is first connected to ground power heaters warm the water system, including the filler nipple, to prevent it from freezing. It definitely works down to minus 27C. The heaters cycle through various schedules all the time the aircraft is powered. The other items are the brakes, that are left off, and and the batteries. The aircraft's manuals state how the batteries should be handled although it is generally easier and cheaper to keep the aircraft powered during a nightstop.
Piltdown Man is offline  
Old 30th Mar 2017, 20:56
  #15 (permalink)  
 
Join Date: Jan 2011
Location: France
Posts: 191
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by ExXB
In the days of piston engines ground crews in Northern Canada would often have to pre-heat the engines using blow torches. Pesky things don't work with frozen oil.
If the OP wants to work through episodes of the Buffalo Airways "reality" series, there's at least one episode devoted to getting one of their aircraft warmed up enough to fly.
CelticRambler is offline  
Old 1st Apr 2017, 18:18
  #16 (permalink)  
 
Join Date: Feb 2008
Location: Stockport
Age: 84
Posts: 282
Likes: 0
Received 0 Likes on 0 Posts
I seem to recall mention in the distant past of draining the oil from a piston engine whilst it was still warm enough to flow, then in the morning starting up without oil (which would heat things up very rapidly) and pour the oli in once things were running. My source could have been "Biggles Flies North" of some similar tome, but I would be interested to know if the procedure was based on reality.
Dairyground is offline  
Old 1st Apr 2017, 21:05
  #17 (permalink)  
Paxing All Over The World
 
Join Date: May 2001
Location: Hertfordshire, UK.
Age: 67
Posts: 10,143
Received 62 Likes on 50 Posts
I seem to recall that the process of draining oil from a piston engine and then pre-heating the oil before returning to the engine - critically starting the engine and then tipping the pre-heated oil in a second later! was described by Nevil Shute in An Old Captivity.
PAXboy is offline  
Old 1st Apr 2017, 22:01
  #18 (permalink)  
 
Join Date: Aug 2001
Location: se england
Posts: 1,578
Likes: 0
Received 48 Likes on 21 Posts
If I remember correctly the City in the Sky program on Russia shopwed the ground crew pouncing on the wheels as soon as it was on stand to put upa sort of blow up tent around the tires even on turnaround -I think they and or the brakes stil had some nheat from the landing and they wanted to capture that but they wouldn't let the tyres cool , it was like minus 33 where they were, even on a turn around let alone overnight
pax britanica is offline  
Old 2nd Apr 2017, 07:40
  #19 (permalink)  
 
Join Date: May 2009
Location: Confoederatio Helvetica
Age: 68
Posts: 2,847
Likes: 0
Received 0 Likes on 0 Posts
Could have been here.

https://www.amazon.com/Bush-Pilot-Br.../dp/1550545868
ExXB is offline  
Old 5th Apr 2017, 22:14
  #20 (permalink)  
 
Join Date: Feb 2017
Location: A small city with a University
Age: 68
Posts: 93
Likes: 0
Received 0 Likes on 0 Posts
The Herman Nelson Engine Pre-Heater has been used for decades in Canada.
Kewbick is offline  


Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.