A-109E Power helicopter hyd. servos leakage rate

Please help with the following ambiguity-what is your opinion/experience?

-Airwortiness Check item 16. calls for inspection of bleed holes for leaks from flight control servoactuators. (once a day)
-Maintenance Manual in Ch. 67-31-9 inspection (Fig. 67-59) says that hyd. fluid leakage from bleed holes (16 and 17) is not permitted - it requires replacement of servoactuator and even notification to AgustaWestland if leakage discovered.
-Maintenance Manual in Ch. 29-00-10 Leakage checks in Table 29-1 defines, that body (weep hole) leakage is allowed with 2 drop / 25 full stroke cycles in dynamic conditions, and in S-D conditions(static leakage through dynamic seal) says: "No drops during the first 4 h"
1. What is meant by this limitation? 4 hours after last flight there shall be no leaks, but after a night in the hangar, leak is acceptable? 4 hours after installation of new OH actuator there shall be no leaks????
2. So, what should a maintenance technician do when performing Airworthiness check in the morning and discovers fluid leakage from bleed hole (weep hole) of rotor servoactuator?
-declare helicopter unairworthy and replace actuator?
-perform leakage test with ground power unit, to determine dynamic leakage rate? If yes, when to repeat such check, if first check determines, that leakage is within limits (less than 2 drop per 25 full cycles)?????

I checked with several maintenance engineers, that finished A-109E type rating course at AgustaWestland facility, and they all claimed, that they were instructed, that no leakage is permitted at weep holes of mentioned servoactuators.

Comments / suggestions well appreciated. Please do not point me towards AgustaWestland, as there was no response so far. (one month after inquiry)
hoistop is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.