PPRuNe Forums - View Single Post - SAR S-92 Missing Ireland
View Single Post
Old 14th Mar 2017, 10:57
  #13 (permalink)  
terminus mos
 
Join Date: May 2012
Location: Aer
Posts: 431
Likes: 0
Received 0 Likes on 0 Posts
Mitchaa


I understand the only safeguard in place is a bearing energy monitoring tool in the HUMS system.
Not exactly. HUMS download after each flight. Max 6 hours between downloads. 10 flying hour boroscope inspection. Some aircraft now getting temperature sensors on the bearing.